维维

verify-tagSolar Radiation Spectrum 2018-2023

renewable energytime series analysistabular

1

已售 0
81.96MB

数据标识:D17222519610262564

发布时间:2024/07/29

以下为卖家选择提供的数据验证报告:

数据描述

TSIS-1 SIM Solar Spectral Irradiance V09 ; ; SELECTION CRITERIA ; date range: 20180314 to 20230129 ; cadence: 24 hours ; spectral range: 200.0 to 2400.0 nm ; number of data: 3307488 ; identifier_product_doi: 10.5067/TSIS/SIM/DATA318 ; identifier_product_doi_authority: http://dx.doi.org/ ; END SELECTION CRITERIA ; ; DATA DEFINITIONS, number = 11 (name, type, format) ; nominal_date_yyyymmdd, R8, f11.2 ; nominal_date_jdn, R8, f11.2 ; wavelength, R4, f9.3 (nm) ; instrument_mode_id, I2, i3 ; data_version, I2, i3 ; irradiance_1AU, R8, e15.8 (W/m^2/nm) ; instrument_uncertainty, R8, e15.8 (W/m^2/nm, 1 sigma) ; measurement_precision, R8, e15.8 (W/m^2/nm, 1 sigma) ; measurement_stability, R8, e15.8 (W/m^2/nm, 1 sigma) ; additional_uncertainty, R8, e15.8 (W/m^2/nm, 1 sigma) ; quality, UI2, i6 ; END DATA DEFINITIONS ; ; Background on the Total and Spectral Solar Irradiance Sensor (TSIS-1) ; ; The Total and Spectral Solar Irradiance Sensor (TSIS-1) level 3 (L3) data product is constructed ; using measurements from the Total Irradiance Monitor (TIM) and Spectral Irradiance Monitor (SIM) ; instruments. The TIM instrument measures the total solar irradiance (TSI) that is incident at the ; outer boundaries of the atmosphere and the SIM instrument measures the solar spectral irradiance ; (SSI) from 200 nm to 2400 nm, which are combined into 12-hr and 24-hr solar spectra. The TSIS-1 data ; products are provided on a fixed wavelength scale, which has a variable resolution over the ; spectral range. Irradiances are reported at a mean solar distance of 1 AU and zero relative line-of- ; sight velocity with respect to the Sun. ; ; Table: Solar Spectral Irradiance (SSI) Measurement Summary. ; ; Measuring Instrument SIM ; Temporal Cadence Daily ; Detector Diodes (200 nm to 1620 nm), ESR (1620 nm to 2400 nm) ; Instrument Modes 86 (UV), 85 (VIS), 84 (IR), 83 (ESR) ; Spectral Range 200 nm to 2400 nm ; ; The spectral irradiances are tabulated below ("DATA RECORDS"), with each row giving the nominal date ; (YYYYMMDD.D), nominal date (Julian Day), wavelength center (nm), instrument mode, data version, ; spectral irradiance @ 1au (irradiance_1AU, Watts/m^2/nm), instrument_uncertainty (Watts/m^2/nm), ; measurement_precision (Watts/m^2/nm), measurement_stability (Watts/m^2/nm), additional_uncertainty ; (Watts/m^2/nm), and a "quality" (data quality flag) value. Measurement_stability is given as ; 0.00000000e+00 (0.0) at wavelengths > 1050 nm, where we do not currently calculate a degradation ; correction, and for all data that arrives after the bi-annual Channel C calibration scans. The ; bi-annual Channel C scans trigger a new data release version, so there could be up to six months of ; measurement stability values that are 0.0 until determined during the creation of the next data release. ; Data quality flags are assigned to each spectral measurement in the 'quality' column. The value in this ; column is the addition of all the bit-wise data quality flags (DQF) associated with a given measurement. ; Nominal data has a DQF of '0'. The L3 TSIS-1 SIM data quality flags are: ; ; VALUE CONDITION ; ----- --------- ; 1 Missing data ; 2 Backfilled data (from previous day) ; 512 Data taken with offset pointing; a spectral correction has been applied ; ; Data with the '512' bit set was taken from March 19, 2022 through May 19, 2022. During this period, ; the TSIS-1 SIM pointing was off by ~1 arcmin due to external contamination of the pointing system ; quad-diode (HFSSB). A wavelength-dependent correction has been applied to data during this period, ; and the corresponding additional irradiance uncertainties associated with this correction are given ; in the 'additional_uncertainty' column. Note that it is possible that multiple flags can be set on ; the same measurement. For example, a quality of '514' is backfilled data, and the data used was taken ; during the offset pointing. ; ; Instrument_uncertainty, measurement_precision, measurement_stability, and additional_uncertainty are ; all in units of (Watts/m^2/nm). ; ; Each field (column) is defined and further described in the "DATA DEFINITIONS" section. ; ; An IDL file reader (http://lasp.colorado.edu/data/tsis/file_readers/read_lasp_ascii_file.pro) is ; available which will read this file and return an array of structures whose field names and types ; are taken from the "DATA DEFINITIONS" section. ; ; Erik Richard (2023), Level 3 (L3) Solar Spectral Irradiance Daily Means V009, ; Greenbelt, MD, USA, Goddard Earth Sciences Data and Information Services Center (GES DISC), ; Accessed [Data Access Date] at http://dx.doi.org/10.5067/TSIS/SIM/DATA318 ; ; For more information on the TSIS-1 instruments and data products, see: ; http://lasp.colorado.edu/home/tsis/ ; ; This data file, release notes, and other TSIS-1 data products may be obtained ; from: http://lasp.colorado.edu/home/tsis/data/ ;

formated with https://github.com/TavoGLC/datasets/blob/main/wavelengths.py

data icon
Solar Radiation Spectrum 2018-2023
1
已售 0
81.96MB
申请报告